Type:230,231,232 series Coated Thickness Meter
Illustrate: Ribot coated thickness meter with magnetic and eddy current two methods for measurement of thickness, Can be measure the thickness of magnetic metallic coatings on
CX-CTG-230,231,232 Coated Thickness Meter
Main function:
Ribot coated thickness meter with magnetic and eddy current two methods for measurement of thickness, Can be measure the thickness of magnetic metallic coatings on non-magnetic cover layer nondestructively. (such as steel, iron, alloy and hard magnetic steel with aluminum, chromium, copper, zinc, tin, rubber, paint and so on ), and thickness of the Non-magnetic metal with non conductive insulating cover layer (such as aluminum, copper, zinc, tin, rubber, plastic, on the rubber, plastic ,oil print, oxidation film etc.).
●All English menu;
●2 types measuring method;
●2 types working method;
●Memory up to 500 ocs measurement value;
●Data delete function;
●Can set the limits;
●can automatic alarm for measurement value
of out of limits;
●Undervoltage indication of power;
●Manual and automatic power off.
Technical parameter:
Main function:
Ribot coated thickness meter with magnetic and eddy current two methods for measurement of thickness, Can be measure the thickness of magnetic metallic coatings on non-magnetic cover layer nondestructively. (such as steel, iron, alloy and hard magnetic steel with aluminum, chromium, copper, zinc, tin, rubber, paint and so on ), and thickness of the Non-magnetic metal with non conductive insulating cover layer (such as aluminum, copper, zinc, tin, rubber, plastic, on the rubber, plastic ,oil print, oxidation film etc.).
●All English menu;
●2 types measuring method;
●2 types working method;
●Memory up to 500 ocs measurement value;
●Data delete function;
●Can set the limits;
●can automatic alarm for measurement value
of out of limits;
●Undervoltage indication of power;
●Manual and automatic power off.
Technical parameter:
CTG-230 | CTG-231 | CTG-232 | ||
Measuring head type | F1 | N1 | F1 or N1 | |
Operational principle | Magnetic induction | Eddy current |
Magnetic induction or Eddy current |
|
Measuring range | 0~1250μm | |||
Lower limit resolution | 0.1μm | |||
Indication error | One-point Calibration | ±(3%H+1) | ||
Two-point calibration | ±[(1~3%)H+1] | |||
Measure conditions | The mini. radius of curvature(mm) | protrude1.5,concave 9 | ||
Mini. area dia.(mm) | Φ7 | |||
Basic critical thickness(mm) | 0.5 | |||
Working environment | Temp. | 0~40℃ | ||
humidity | 20%~90% | |||
Power supply | AA alkaline batteries 1.5V(2 pcs) | |||
housing | Metal housing | |||
Overall dimension | 150×55.5×23mm(main body) | |||
weight | F1/320g,N1/360g | |||
standard configuration |
Main body, “AA” alkaline batteries, standard test block, basal body |
|||
Optional configuration | - | - | All kind of the probe |