Type:Industrial Dissolved Oxygen Meter
Illustrate:CX-IDO-1301A Industrial Dissolved Oxygen Meter is a kind of on-line instrument that is used for water quality analysis and monitoring and is equipped with a microprocessor.
CX-IDO-1301A Industrial Dissolved Oxygen Meter
Features:
Large vacuum fluorescent display (VFD), Chinese menu, and man-machine interaction function.
There are application analysis for the electrode and four calibration methods.
The functions of automatic temperature compensation and automatic range switching.
Available with history curve, real-time trend chart and clock.
There are four kinds of built-in recorders. It is available with isolated current output and alarm.
The user can set the password or consult the “Help” menu or the “Service Guide” Menu.
It has power-off protection. The data can be saved for 5 years under a continuous power-failure condition.
The communication interface can be connected directly to a computer and enables remote operation and control.
The instrument adopts universal module power supply.
It is equipped with the dissolved oxygen electrode with excellent technical performance and stable and reliable
measuring capacity. It can be easily used and maintained.
Technical indexes:
1. Measuring range and error: dissolved oxygen: 0-20µg/L; 0-200µg/L; 0-20mg/L (automatic range switching).
Resolution: 0.1µg/L; error: ±0.2 µg/L
Resolution: 0.01 mg /L; error: ±0.02 mg/L
Temperature: 0~60℃; resolution: 0.1℃; error: ±0.8℃
2. Range of automatic temperature compensation: 0~60℃, with 25℃ as the reference temperature
3. Residual signals of the electrode: <1‰ (air signal at room temperature).
4. Response time (90% of the final value): When the temperature is 25℃, the response time <60s; when the
temperature is 35℃, the response time <30s.
5. Stability: Under normal pressure and constant temperature, the weekly shift should be <2%F.S.
6. Water sample pressure: 0.6MPa
7. Isolated output: 0-10mA (load resistance <1.5KΩ).
4-20mA (load resistance<750Ω).
8. Data storage capacity: 55 hours (1 point/10 seconds); 14 days (1 point/1 minute)
68 days (1 point/5 minutes); 412 days (1 point/30 minutes)
9. Normally-open contact of the alarm relay: 3A 240V AC, 6A 28V DC or 120V AC
10. Overall dimension of the electrode unit: 151 (length) x 151 (width) x 251 (height) mm
11. Dimension of the mounting hole of the electronic unit: 138 x 138mm
12. Weight of the electronic unit: 1.2kg
13. Power supply: 85-265VAC 50±1Hz
14 The connection pattern of the inlet and outlet water pipes: Pipe diameter: Φ6, Φ8, Φ10, Φl2 and Φl4.
More sensor types and installation methods are: [flow-through type][duct-type][ plug-in type]