Location -> Industrial online analyzer -> 2.Chlorine sensor

Type:Free Chlorine Sensor without film
Illustrate:FreeChlorineSensorwithoutfilm (on-linechlorinesensor) Features: Noneedofchemical Withoutfilm.Notinflurencedbysurfactant Notmiropoloe.Itwillnotbeplugbymircoimpurity. Standard2-wire4-20mAoutput Easymaintenance Temperaurecompensation Noneedof..
Free Chlorine Sensor without film
(on-line chlorine sensor)
Features:
Application:
Installation: Flow cell installation
Maintenance
Wiring: standard 2-wire
Sensor structure
(on-line chlorine sensor)
Features:
- No need of chemical
- Without film. Not influrenced by surfactant
- Not miropoloe. It will not be plug by mirco impurity.
- Standard 2-wire 4-20mA output
- Easy maintenance
- Temperaure compensation
- No need of pressure balance
- range:0-0.5/2/5/10/20/50ppm or to be customized
- material:POM、PTFE、Gold、Silver,Conductive rubber
- accuracy: ±0.1%FS
- responding time:1-60 second(90% of all response)
- temperature:5-50℃
- electrolyte working life:1 year
- output:4-20mA
- power supply:12-24V
- flow rate:20-40l/h
- interface:standard 2-wire or 4-wire
- size:φ25*140mm
- installtion way:flow cell installation
- calibration:1 point slope rate calibration,no need of zero point calibration
Model | range | resolution | ph | Film or not |
CX-CS-WCL-01 | 0.01-0.5 ppm | 0.001ppm | 5-8 | No |
CX-CS-WCL-02 | 0.02-2.00ppm | 0.001ppm | 5-8 | No |
CX-CS-WCL-03 | 0.05-5.00ppm | 0.01ppm | 5-8 | No |
CX-CS-WCL-04 | 0.1-10.00ppm | 0.01ppm | 5-8 | No |
CX-CS-WCL-05 | 0.2-20.00ppm | 0.01ppm | 5-8 | No |
CX-CS-WCL-06 | 0.5-50.00ppm | 0.01ppm | 5-8 | No |

Application:
- Drinking water
- sewage
- pools
- natural water
Installation: Flow cell installation
Maintenance
- calibration:to calibrate with DPD way
- maintenance of working electrode surface:to wash the surace with small toothbrush every month
- electrolyte replacement:to be replaced each year
Wiring: standard 2-wire

Sensor structure

Last:Chlorine Electrode Next:CL80A/CL80B Chlorine Controller